Turbidity Meter
Product Details :
Product Code : HI-98703
Leveraging upon our technical know-how, we are engaged in manufacturing and supplying Turbidity Meter. This meter is used for measuring the turbidity of drinking water in laboratory. Best quality materials and components are used to manufacture this device. The device has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. The last calibration points, time and date can be checked in this device at the touch of a button. We offer Turbidity Meter at pocket friendly prices to clients.
Features:
- User friendly
- Sturdy in nature
- Resistant to breakage
Further Details:
- The HI 98703 meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.
- This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button.
Product Details:
- High accuracy at low ranges (below 0.05 NTU)
- Two, three or four point calibration
- USB and RS232 PC connectivity
- Log up to 200 records
- GLP Features
- User friendly, backlit display with guidance codes
- Battery % on startup
- Continuous current time on display
Specifications:
- Range : 0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
- Range Selection : automatic
- Resolution : 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
- Accuracy @25°C : ±2% of reading plus 0.02 NTU
- Repeatability : ±1% of reading or 0.02 NTU, whichever is greater
- Stray Light : < 0.02 NTU
- Light Detector : silicon photocell
- Light Source : tungsten filament lamp
- Lamp Life : greater than 100,000 readings
- Method : Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method : 180.1 and Standard Method 2130 B
- Measuring Mode : normal, average, continuous
- Turbidity Standards : <0.1, 15, 100 and 750 NTU
- Calibration : two, three or four-point calibration
- Log Memory : 200 records
- PC Connectivity : USB or RS232
- Environment : up to 50°C (122°F); RH max 95% non-condensing
- Power Supply : 1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
- Dimensions / Weight : 224 x 87 x 77 mm (8.8 x 3.4 x 3.0â€) / 512 g (18 oz.)