Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter

Product Details:

Minimum Order Quantity1 Unit
BrandAI Scientific
ModelAI-3689
Dimension600 mm x 460 mm x 430 mm
Temperature measurement range10 degree c ~ 35 degree c
Ambient humidityLess than 85%
Total power consumptionLess than 150w
Power supplyAc(220+/-5%)v, 50hz
Pressure endured by oxygen bomb20 mpa


Oxygen Bomb Calorimeter

AI-3689
            The instrument uses a single-chip control technology, color LCD display, high-precision temperature sensor and high-performance A / D conversion device, consisting of a high degree of automation, screen effect is good, easy to use, convenient intelligent data compilation instrument. 2. The instrument is fully automated in the testing process, after the sample in place, correct input various parameters automatically without manual intervention to complete each test process; you can print measurement data directly on the A4-format printer configuration after the end of the trial. 3. This instrument adopts the self sealing type oxygen bomb, all the structure is made of stainless steel, and the strength is enough to withstand the pressure test of 20MPa at room temperature. 4. The inner tube of the instrument is made by stainless steel sheet, section of pears, put the barrel of water was 3000 grams, water cylinder with electric blender, to ensure that the inner tube water bath temperature uniformity. 5. The instrument of the external water jacket is a double container and experiment when filled with water, through the water jacket mixer to cylinder in uniform temperature, formed to meet the test requirements of the constant temperature environment.

Main technical specifications :

  • Heat capacity: (14000~15000) J/K;
  • Temperature resolution: 0.001 K;
  • Thermal error: ≤60J/g;
  • Repeatability error: ≤0.2% (Grade C);
  • Ambient temperature: 15 ℃~28 ℃ (room temperature), The temperature fluctuation during each test should be not more than 1 ℃;


Request


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)

Write a review

Note: HTML is not translated!