Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Water Analyzer Model 371 Systronics

Water Analyzer Model 371 Systronics

Product Details:

Minimum Order Quantity1 Piece
Model371
ApplicationLaboratory Use, Industrial Use
BrandSystronics
PH Range0 to 14.00 pH
Resolution0.01 pH
Accuracy+/-0.01 pH +/-1 Digit
SensorCombined Electrode
Display2 Line 20 Char LCD Alphanumeric
Printer PortEpson Compatible 80 column D.M. Printer
Power230V 50Hz +/-10% or Internal Battery With charger
DimensionW420xD520xH175 mm
Weight9 Kg (Approx)


The advantages of the Water Analyzer 371 at a glance:

  • Micro controller Based
  • Measures pH
  • Measures mV / ORP
  • Measures Conductivity / TDS
  • Measures Salinity
  • Measures Dissolved Oxygen
  • Measures Temperature
  • Measures Colorimeter
  • Measures Turbidity

 

mV / ORP :

  • Range : 21988 mV
  • Resolution : I mV
  • Accuracy : +/-1 mV +/-1 Digit
  • Sensor : Combined Electrode


Conductivity /TDS:

  • Range : 0 to 100 mS (5 range.) 0 ppm to100 ppt (5 ranges) at TDS factor 0.5 (Approx) & TEMPCO 2%
  • Accuracy : +/-1% of FS +/-1 Digit
  • Sensor : Conductivity Cell (Acceptable from 0.1 to 5.0 cell constant)
  • Temp. Compensation : Auto/ Manual


Salinity:

  • Range : 0 to 40 ppt
  • Resolution : 0.1 ppt
  • Accuracy : +/-2% of FS +/-1 Digit
  • Sensor : Conductivity Cell (Acceptable from 0.1 to 5.0 cell constant)
  • Temp. Compensation : Auto/Manual


Dissolved Oxygen:

  • Range: 0 to 20 ppm
  • Resolution : 0.1 ppm
  • Accuracy : +/-1% of FS +/-1 Digit +/-0.1
  • Sensor : Au / Ag Probe
  • Temp. compensation : Auto/ Manual


Temperature:

  • Range : 0 to 100 Deg C
  • Resolution : 0.1°C
  • Accuracy : +/-0.5° C +/-1 Digit
  • Sensor : PT 100

 

Colorimeter:

  • Range : 0 to 2.00 Abs 0 to 100 %T Conc :0 to 1999
  • Accuracy : ±.0.05 Abs
  • Resolution : 0.001 Abs /0.1 %T
  • Sensor : Photodiode
  • Source : Tungsten Larne
  • Filters : Blue (440 nm) Green (540 nm) Red (660 mm)


Turbidity:

  • Range : 0 to 1 NTU, 0 to 10 NTU, 0 to 100 NTU
  • Accuracy : +/-2% of FS
  • Sensor : Photodiode
  • Source : Tungsten lamp