Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Pro Tens + Stim LCD

Pro Tens + Stim LCD 

Product Details : 

  • 78 Protocol
  • 100 Memory
  • Continuous TENS
  • Burst TENS
  • Auto TENS - Linear
  • Auto TENS - Trapezoidal
  • Auto TENS - Non Linear
  • Plain Galvanic
  • Int Therapeutic Galvanic
  • Int Diagnostic Galvanic
  • Plain Faradic
  • Surge Faradic
  • Iontophoresis
  • Ultrareiz Current
  • Diadynamic
  • Cable Test Facility
  • Electrode Test Facility
  • Patient Interrupt Switch

Specification

  • TENS - Continuous 
  • Frequency - 250 Hz (2 - 999 Hz in step of 1 Hz)
  • Pulse Width - 200 µS (20 to 800 µS in step of 10 µS)
  • Save Settings Yes - No

TENS - Burst 

  • Frequency - 250 Hz (2 - 999 Hz in step of 1 Hz)
  • Pulse Width - 200 µS (20 - 800 µS in step of 10 µS)
  • Burst Time - 5 Secs (2 - 10 Secs in step of 1 Sec)
  • Burst Ramp Time (0.5 Second)
  • Save Settings Yes - No

Auto TENS (Linear / Trapezoidal / Non Linear)

  • Base Frequency - 250Hz (2 - 500 Hz in step of 1 Hz)
  • Pulse Width - 200 µS (20 - 800 µS in step of  10 µS)
  • Sweep Frequency - 250 Hz (2 - 500 Hz in step of 1 Hz)
  • Sweep Time - 4 - 8 - 12 Second
  • Save Settings Yes - No

Galvanic - Plain 

  • Direct DC Current
  • Save Settings Yes - No

Galvanic - Intermittent

  • Pulse Width - 100 mS (30 - 300 mS in step of 10 mS)
  • Off Time - 1 Sec (0.5 - 6 Secs in step of 0.5 Sec.)
  • Save Settings Yes - No

Faradic - Plain 

  • Frequency - 50 Hz (Fixed)
  • Pulse Width - 0.7 mS (Fixed)
  • Save Settings Yes - No

Faradic - Surge 

  • Frequency - 50 Hz (Fixed)
  • Pulse Width - 0.7 mS (Fixed)
  • Surge On/Off Time - 5 Sec (1 - 10  Secs in step of 1 Sec)
  • Surge Ramp Time - 0.5 Sec
  • Save Settings Yes - No

Galvanic Diagnostic & Therapeutic - Int

  • Pulse Frequency - 1Hz
  • Pulse Width - 300 mS. 
  • (.01, .03, .1, .3, 1, 3, 10, 30, 100, 300, 1000 mS.)
  • Off Time - 1 Sec. (0.5 - 6 Secs. in step of 0.5 Sec.)
  • Save Settings Yes - No

Special Feature -

  • During the treatment time also, provision provided to select the pulse width  by using SELECT key and thereby enable to vary the pulse width using “UP” & “DN” Keys.

Iontophoresis

  • Direct DC Current
  • Save Settings Yes - No


Ultrareiz Current

  • Frequency - 143 Hz. (Fixed)
  • Pulse Width On Time - 2 mS. (Fixed)
  • Pulse Width Off Time - 5 mS. (Fixed)
  • Save Settings Yes - No

Diadynamic

  • MF (50 Hz Halfwave) DF (100 Hz Fullwave)
  • CP (Alter. of 50 Hz - 100 Hz)
  • LP (Auto. linear of 50 Hz - 100 Hz)
  • Save Settings Yes - No


Write a review

Note: HTML is not translated!
    Bad           Good

Pro Tens + Stim LCD

  • ₹0

Seller information

  • International Electro Medical Co

  • International Electro Medical Co.
  • New Delhi, India
  • Business Type :Supplier
View profile
Please sign in to contact International Electro Medical Co

Tags: Pro Tens + Stim LCD