Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Online Stack Monitoring Systems

Online Stack Monitoring Systems

Product Details:

BrandApplied Techno Systems
Power Source230VAC
Response Time<5 Second
Weight2.5 Kg
Country of OriginMade in India
Anolog Out Put4-20 mA
Humidity< 85%RH
Dimensions430 X 150 X 250 mm (W x H x D)


We offer comprehensive range of Online Stack Monitoring Systems and Continuous for the analysis of stack/flue gases in exhaust, boiler and combustion process. Model ATS- 206A Flue gas Analyzer measure the flue gases after placing its probe into stack or appliance exhaust and see the concentration of Oxygen (O2), Carbon Monoxide (CO) Carbon Dioxide (CO2). Efficient combustion also reduces emission of pollutants such as nitric oxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2), and particulate matter. A gas analyzer will also help measure various gas pollutants in the exhaust for environmental reasons.
  • Microcontroller based embedded intelligent instruments
  • Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2
  • Duel wavelength Infra red sensor for Long terms accuracy and stability
  • Long Life Electrochemical sensor
  • Six Gas Analysis in Single Analyser
  • Multi Parameter Single 320 X 240 Graphics LCD Display
  • Self diagnostic & Self integrity check
  • RS 232/RS 485 and USB Computer Interface
  • Excellent low level capability for NOX and SO2 Measurement
  • For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.
  • Analog 4-20mA output for each gas
 
Specifications:
  • Principle: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic
  • Range: %V/V, % LEL, PPM, Mg/M3
  • Resolution: 0.1 Unit or 1 Unit (Application based)
  • Sampling Method: Auto Suction
  • Display: 320 X 264 Graphic LCD
  • Alarm; Relay Contact NO NC
  • Anolog Out Put: 4-20mA
  • Digital Out Put : RS 232, RS 485 and Modbus Comminication Protocol
  • Power Source:230VAC
  • Accuracy: /2%
  • Response Time: <5 Second
  • Sensor Life: 2-3 Years
  • Environmental:Temperature:-15degree Celsius 
  • Humidity :< 85%RH 
  • Atmosphere Pressure: 86- 106Kpa
  • Dimension in mm: 430 (W) X 150(H) X 250(D)
  • Weight: 2.5 KG
  • Warranty: One Year