Click Image for Gallery
Aluminium Load Cells
Product Details:
Product Details:
Input Resistance | 400 +/- 15 ohms |
Excitation Voltage | 10vdc-max. 15vdc |
Brand | Goldtech |
Standard capacities | 100,150 -kgf |
Safe overload of related capacity | 150.00% |
Cable length (4 core screened) | 250 cm |
Ultimate overload of rated capacity | 200.00% |
Normal Output | 2.0 mv/v |
Capacity | 100,150 -kgf |
Features:
- Sturdy construction
- Hassle-free operation
- High functionality
Other Details:
Standard capacities | 100, 150 -kgf |
Excitation voltage | 10vdc-max. 15vdc |
Normal output | 2.0 mv/v |
Non - linearity | < ± 0.025% fso |
Hysteresis | < ± 0.02% fso |
Non - repeatability | < ± 0.01% fso |
Creep (30 minutes) | < ± 0.03% fso |
Zero balance | ± 1.0% fso |
Input resistance | 400 ± 15 ohms |
Output resistance | 350 ± 5 ohms |
Insulation resistance (50vdc) | > 1000 mega ohms |
Temp compensated range | 0-60ºc |
Temperature effect on output | < 0.0015% fso/ºc |