Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Lab Bio Safety Cabinets

Lab Bio Safety Cabinets

Product Details :


Bio Safety Cabinets Class III

Bio Safety Cabinet Class III (Glove Box)

We offer Class III Bio Safety Cabinets are provide total barrier protection for the operator, Product, environment and are suitable for extreme bio-hazard group 4 work. Class III biological safety cabinets are Air-tight and inflow air is HEPA filtered before entering the Class 3 Biological Safety Cabinet via a side mounted inlet filter chamber. Exhaust air is HEPA filtered before leaving the safety cabinet via a single or double HEPA filter, dependant on the customer’s specific technical requirements. According to the Filter life and Energy saving, we having 3 models are …………..

1. Basic Model 2. Standard Model 3. Superior Model  

  • Total enclosure of the working area
  • User separated from the work by a physical barrier
  • Filtered air continuously supplied to the safety cabinet
  • Exhaust air treated to prevent contamination
  • Creates total protection for user and materials
  • Manipulations within the Class 3 Biological Safety Cabinet are carried out via gloves mechanically attached to the cabinet providing a total seal against any particulate contamination released within the main working area. Only Class 3 cabinets which are totally enclosed units are suitable for work with Group 4 hazards.

 

MOC of Construction :

1. Fully SS 304 construction with PVC mat 4 finish.

2. GI Powder coating / Painting Constriction with SS 304 working area and work bench.

 

Technical Specifications :

  • Direction of flow : Vertical
  • Cleanliness : CLASS 100
  • Air Balancing : 0% recirculation and 100% Fresh air
  • Inflow Velocity : 0.53 M/s
  • Down flow Velocity : 0.33 M/s
  • HEPA Filter : 0.3micron with 99.997% efficiency
  • Particle retention : Above 0. 3 micron
  • Blower Assembly : 1 / 3 HP, 1440 RPM
  • Noise level : 65 decibel + / -5%
  • Vibration level : < 2. 5 micron

 

Fittings :

  • Microprocessor based Control systems and feather touch switches 
  • RPM regulator / VFD controller
  • Magnehelic Gauge / Mano meter and Gas Nipple
  • Velocity sensors and Digital display systems
  • CFL Lighting and Germicidal (UV) Lamp with Hour meter

 

Clients : 

  • Medical Testing Lab, Hazardous material handling area, Blood testing labs etc.,