Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Environmental Air Calibration Standards

Environmental Air Calibration Standards

Product Details :

Certified and primary calibration gas standards are used for instrument calibration and other monitoring and measurement applications where either use of an EPA Protocol calibration standard is not required or an EPA Protocol standard is not available.

As with all Spectra environmental standards, Certified Environmental Calibration Standards are produced gravimetrically directly traceable to NIST standards in cylinders that have been individually passivated by the proprietary Spectrashield™ process.

In addition, where NIST or comparable international standards are available, analysis are performed utilizing these international standards. Where standards are not available from international metrology organizations, Spectra employs in-house developed analysis technology and standards to provide you with the most accurate and reliable standards available.


Each cylinder is individually analyzed and supplied with a Certificate of Analysis (C of A).

TYPICAL SPECIFICATIONS

CERTIFIED STANDARDS

PRIMARY STANDARDS

Concentration RangeBlend ToleranceAnalysisBlend ToleranceAnalysis
< 100 ppbConsult factoryConsult factoryConsult factoryConsult factory
100 ppb to 999 ppb± 20%± 10%± 10%± 5%
1 ppm TO 9999 ppm± 10%± 5%± 5%± 1%
1%± 5%± 2%± 1%± 0.02% absolute


Certified and primary calibration gas standards are available in size 2A, 3A, and 4A aluminum cylinders and where appropriate in size 2, 3, and 4 internally polished and passivated steel cylinders.

All certified and primary calibration gas standards are filled to the maximum pressure and volume as determined by the cylinder, the vapor pressure of the mixture, or restrictions due to flammable-oxidizer (flam-ox) requirements.


ComponentBalanceAvailable Concentrations
Ammonia(NH3)Zero Air25 ppm to 6% 2
Ammonia(NH3)N21 ppm to 10% 2
Benzene (C6H6)Zero Air1 ppm to 1000 ppm 1,2
Carbon Dioxide(CO2)Zero Air1 ppm to 20%
Carbon Dioxide(CO2)N21 ppm to 20%
Carbon Monoxide(CO)Zero Air500 ppb to 3% 2
Carbon Monoxide(CO)N2500 ppb to 20%
Ethylene Oxide (C2H2O)N21 ppm to 1%1
Hexane (C6H10)Zero Air100 ppb to 5000 ppm1
Hexane (C6H10)N210 ppb to 5000 ppm2
Hydrogen Chloride (HCl)N210 ppm to 1%
Hydrogen Chloride (HCl)Zero Air10 ppm to 1%
Hydrogen Sulfide (H2s)Zero Air5 ppm to 1000 ppm
Hydrogen Sulfide (H2s)N21 ppm to 3%
Mercury (Hg)Zero Air2 µg/m3 to 60 µg/m3
Methane (CH4)Zero Air/ N21 ppm to 2.5%2
Methane (CH4)N21 ppm to 10%
Nitric Oxide (NO)N2500 ppb to 2%
Nitrogen Dioxide (NO2)Zero Air25 ppm to 0.5%
Phosphine (PH3)N2100 ppb to 1000 ppm
Propane (C3H8)Zero Air10 ppb to 1%12
Propane (C3H8)N210 ppb to 25%
Sulfur Dioxide (SO4)Zero Air5 ppm to 2%
Sulfur Dioxide (SO4)N2100 ppb to 1%
Sulfur Hexafluoride(SF4)Zero Air1 ppm to 10%
Sulfur Hexafluoride(SF4)N21 ppm to 10%
Toluene (C6H5CH3)Zero Air1 ppm to 100 ppm1
Toluene (C6H5CH3)N225 ppb to 100 ppm1
Vinyl chloride (C2H3CI)Zero Air100 ppb to 2000 ppm1
Vinyl chloride (C2H3CI)N2100 ppb to 2000 ppm1


1. Vapor pressure constraints will limit fill pressure/volume at higher concentrations of this standard

2. Flam/ox constraints will limit fill pressure/volume at higher concentrations of this standard.

Write a review

Note: HTML is not translated!
    Bad           Good

Environmental Air Calibration Standards

  • Views: 60
  • Product Code: SBI0000041
  • Availability: In Stock
  • ₹0

Seller information

  • Spectro Biotek Instruments

  • Spectro Biotek Instruments
  • Delhi, India
  • Business Type :Supplier
View profile
Please sign in to contact Spectro Biotek Instruments

Tags: Environmental Air Calibration Standard