Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Microprocessor Water Testing Kit

Microprocessor Water Testing Kit

Product Details :


Applicationpharmaceutical, Laboratory Use, Industrial Use
BrandManti
MaterialPlastic
ModelMT-130


MT-130 : It is Used For measuring the pH , Temp. , D.O , TDS , Salinity , Turbidity , Conductivity , ORP .


Specifications :


pH
Range0 to 14pH
Resolution0.01pH
Accuracy±0.01pH (Relative)
Temp. CompAutomatic With Temp. Probe
BufferManual By Keys
Recognition4.00 7.00, 9.20 pH (Automatic)
Slope Adjustment80% to 120%, By Default 100%
CalibrationAuto/Manual 2-Point, 3-Point
mV (ORP)
Range0 to ±1999mV
Resolution1mV
Accuracy±1
mV CalibrationManual
Temperature
Range-20.0 to +200°C
Resolution0.1°C
Accuracy±0.2%
Input TypePt 100
CalibrationManual
Dissolved Oxygen
Range0 t 20ppm
Resolution0.1ppm
Temperature Comp.Automatic with pt 100probe manual with keys
Pressure Adjustment0 to 999mm of Hg Manual
Salinity Correction0 to 20gm/1 (Manual)
CalibrationAutomatic
Accuracy±2%±1digit
Conductivity
Range0 to 1000m mho in 6-ranges
Range SelectionAutomatic 6 Ranges 0µ mho to 1000m mho
Resolution0.1µ mho
Cell ConstantAdjustable
Temperature co.-effAdjustable between 0 to 4%
Temperature Comp.Automatic for entire range
Accuracy±0.5% of range + 1digit
Turbidity
Range0-100JTU
Resolution1JTU
Accuracy±3% FS ±1digit
Sample Size30mm glass tube
Light6.8V Tungsten Lamp
TDS
Range0 to 200 ppt in 5 Ranges
Range SelectionAutomatic
Resolution0.1 ppm
TDS Factor0.5 and adjustable manuall
SALINITY
Range0 to 50 ppt
Resolution0.1 ppt
Accuracy±0.5% of range + 1digit
Temperature Comp.Automatic
Salinity Factor0.75 and Adjustable Manually
FEATURES
Display16 Character * 2 lines Alphanumeric lcd.
Display FormatTemp pH or temp ORP Simultaneously auto Display of Selected Buffer
SettingBy soft Touch Keys
Storage1000 samples With Date and Time
InterfaceRS-232 Centronics Computer
Real Time Display24 hour Mode With Date
Error IndicationpH error , Buffer Error , ORP Error
Digital Output
  • SERIAL RS-232
  • PARALLEL CENTRONICS
Print Format
  • ALL DATA
  • DATE WSIE
Accessories1) pH Electrode
2) Standard Solution 7.0 pH 4.0 pH
3) ORP Electrode (On Demand)
4) Temeprature Probe
5) Conductivity/TDS/Salinity Cell
6) DO Probe
7) Instruction Manual


Write a review

Note: HTML is not translated!
    Bad           Good

Microprocessor Water Testing Kit

  • ₹0

Seller information

Please sign in to contact Manti Lab Solutions

Tags: Testing Kit