Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Photostability Chamber
Photostability Chamber
Product Details:

For confirmatory studies, samples should be exposed to light providing an overall illumination of not less than 1.2 million lux hours and an integrated near ultraviolet energy of not less than 200 watt hours / square meter to allow direct comparison to be made between drug substance & drug product.
MACK PHARMATECH’s Photostability Chambers are designed specifically to meet ICH & FDA requirements for Photostability testing. Near UV & visible light testing is Approved Approved performed simultaneously according to ICH Q1B option 2.
UV lights get switched off automatically once the door is opened.
You can test the samples on Fluorescent light or U .V lights separately as well as simultaneously.
Uniform light distribution & high intensity levels allow quick response for forced degradation testing and confirmatory studies.
Lights automatically shut off after a specified exposure level or time duration.
Technical Specification
Temperature Range:
20°C - 50°C
Accuracy:
+ 0.2 °C
Uniformity:
+ 1.0°C
Controller System:
PLC BASED CONTROL SYSTEM (Make: Allen Bradley)
CONSTRUCTION
Body & Door Insulation
Poly Urethane Foam (PUF)
Door
Glass Door from inside will be provided to See the samples without any disturbance & SS Door From outside
Chamber Illumination
Fluorescent Tubes are provided in the Chamber
Port Holes
60mm Dia. Porthole Is Provided In the Chamber for Validation
Heating System
S.S. Nichrome Wire Embedded ‘U’ Shaped Air Heater
Refrigeration System
Cooling System Consists Of Condenser & Compressor
Compressor
Hermetically Sealed Compressor Make - Emerson Copeland
Legs
Bullet feet with in-built screwing adjustment are specially
design for long life under heavy load

Standard Features:
  • "CE APPROVED" EQUIPMENT
  • ALLEN BRADLEY MAKE : PLC BASED CONTROL SYSTEM
  • ALLEN BRADLEY MAKE : HMI : LED 4.3" TOUCH SCREEN DISPLAY
  • PRINTING INTERFACE FACILITY
  • PC COMMUNICATION VIA ETHERNET
  • MASTER & STAND BY PT100 SENSORS [MAKE – OMEGA]
  • INDIVIDUAL TIMER FOR LUX & UV

Optional Accessories:

  • 21 CFR PART 11 COMPLIANCE SOFTWARE : DAAS – V 4.0
  • LUX METER
  • UV METER
  • HOOTER SYSTEM ( Security Alarm System)
  • GSM TECHNOLOGY ( SMS Alert System)
  • PASSWORD PROTECTED DOOR ACCESS SYSTEM
Sizes For Photostability with Temperature(◦C)
ModelsMK*-20PHMK*-40PH
Features200 Ltrs400 sLtrs
Interior Dimension  
Width in mm800800
Depth in mm500700
Height in mm600700
Exterior Dimension  
Width in mm960960
Depth in mm11501350
Height in mm13201420
Trays  
No of Zones12
TrayPerforated Type
Power Supply  
Power SupplySingle Phase, 230V 50Hz
Power Rating2KW3KW
Warranty12 Months

Sizes For Photostability with Temperature(◦C) & Humidity (%RH)
ModelsMK*-20PHMK*-40PH
Features200 Ltrs400 sLtrs
Interior Dimension  
Width in mm800800
Depth in mm500700
Height in mm600700
Exterior Dimension  
Width in mm960960
Depth in mm11501350
Height in mm13201420
Trays  
No of Zones12
TrayPerforated Type
Power Supply  
Power SupplySingle Phase, 230V 50Hz
Power Rating2KW3KW
Warranty12 Months

Other sizes also available as on requirement.
MATERIAL OF CONSCTUCTION (MOC)
 
INSIDE MATERIAL
OUTSIDE MATERIAL
INSIDE FINISH
OUTSIDE FINISH
MK – 1
SS 304
GI Powder Coated
Matt Finish
G I Powder Coated
MK – 2
SS 304
SS 304
Matt Finish
Matt Finish
MK – 3
SS 316
SS 304
Matt FinishMat