Click Image for Gallery
Humidity Chamber / Stability Chamber
Product Details:
- Designed for testing product shelf – life, packing and electronic test.
- Specially designed to meet ICH, WHO & USFDA requirements.
- Double walled having Inner 304 SS chamber and Exterior finished in Powder Coated Shade in REGULAR MODEL.
- Inner SS 304/SS 316 and Exterior SS 304 matt/buff finish in GMP MODEL.
- The Temp. & Humidity controlled by Microprocessor based PID Temp. & RH% Controller with Dual Digital Indicator & PT – 100 sensor for Temp. & imported sensor for RH%.
- Cooling Kit is CFC Free. The Cooling Kit includes hermetically sealed compressor, condenser, Fan Motor, etc. and are safely placed below/above the chamber
- Humidification through steam injection system. Humidity levels from 40% RH to 95% RH & depends on Temperature i.e. lower temp. lower humidity higher the temp. higher humidity. Humidity Stability :- 2% RH to ± 3% RH
- Air Circulation system ensures more stability of condition & even distribution inside the chamber.
- A Boiler Tank consisting of Water Heater having auto cut off facility with Audio Alarm for low water level.
- Reservoir Water Tank having float Valve provided.
- Overload protection relay & time delay for compressor.
- Adjustable SS Rod type shelves with all units as standard.
- A two pan glass window provided on door for clear observation of test. An ancillary type heater provided in between the glass to cut the condensation.
- The illumination is provided through fluorescent tubes for clear visibility of test
CAT NO.
INNER SIZE (W X D X HT.)
TEMP. RANGE
RH. RANGE
SHELVES
CAPACITY LTRS.
CAPACITY CFT
CIC - 64
18" x 18" x 28"
10oC - 60oC
40% - 95%
2
150 Ltrs.
5.25 CFT
CIC - 64
24" x 24" x 24"
10oC - 60oC
40% - 95%
3
228 Ltrs.
8 CFT
CIC - 64
24" x 24" x 36"
10oC - 60oC
40% - 95%
3
342 Ltrs.
12 CFT
CIC - 64
24" x 24" x 36"
10oC - 60oC
40% - 95%
4
400 Ltrs.
14 CFT
CIC - 64
36" x 36" x 40"
10oC - 60oC
40% - 95%
5
850 Ltrs.
30 CFT
CIC - 64
38" x 38" x 44"
10oC - 60oC
40% - 95%
6
1040 Ltrs.
36 CFT
Optional
- PRINTER OUTPUT facility required to record PV, SV, Actual Date/Time with variable print time interval, 5000 line memory & Audio alarm facility in case of memory full.
- TEMP. SCANNER 4 Channel/8 Channel with Printer Output facility to record temp. & RH at various places inside chamber.
- PLC Based Touch screenControl System with printer OUTPUT facility
- AUTOCHANGE OVER to stand by Cooling System
- GSM mobile alert.
- 21 CFR PART 11 COMPLIANCE SOFTWARE for Data Management.
- ALARM HOOTER facility.