Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Stability Chamber

Stability Chamber

Product Details :

Model: SSI-120

Complete Body made up of Stainless Steel (304) with Puff Insulation

Temperature Range10ºC to 60ºC
Humidity RangeUpto 80 RH
ICH Conditions• 25ºC / 65% RH
• 30ºC / 65% RH
• 40ºC / 75% RH
• 30ºC / 75% RH
Accuracy± 0.5 0C and 2% RH
Accuracy± 0.5 0C and 2% RH
Uniformity± 1.0 0C and 3% RH
Controller SystemMicroprocessor Based PID Controller
Dry SensorRTD Type (Pt-100)
Wet SensorHumidity capacitance 3.3v volt
Memory6000 Log Memory with Printing Interface (Data logger, Printing Data shows set Value, Actual, Value Date, Month, Year & Time)
Inside Material
Outside Material
Stainless Steel 304 / 22 S.W.G
Stainless Steel 304 / 20 S.W.G
Body & Door InsulationCFC Free Poly Urethane Foam (PUF) 75 mm Thickness Viewing Window Full View Acrylic Observation Door, Chamber Illumination Fluorescent Tube is provided in the Chamber. Port Hole 50 mm dia Porthole is provided on R.H.S of the Chamber for Validation
Heating SystemS.S Nichrome Wire Emended ‘U’ Shape Air Heater. Capacity - 1 Kw (depend upon Chamber size )
Cooling SystemCooling System Consists of Condenser & Compressor, Capillary Type By – Pass System
CompressorHermetically Sealed CFC Free Compressor, Make: Kirlosaker Copeland
Controller SystemTemperature & RH% is controlled by Microprocessor Based PID Controller with Printer Interface Facility & PT-100 Sensor for Dry & RH % Capacitor Type Sensor for Wet Printing Data Shows Set Value, Actual Value Date, Month, Year & Time.


SAFETY FEATURES :

  • For boiler safety system
  • For temperature safety system


SAFETY FEATURES :

Our safety controller is having three safety cut off :

Lower Temperature Cut- Off ( Above Set Point )

Lower Temperature Cut- Off ( Above Set Point )

Lower Temperature cut-off ( Below Set Point ):

  • The LED (LO1) blinks when temperature is undershoot below the lower set
  • Point (Lower cut-off : Below set point)
  • The LED (LO2) blinks when temperature is overshoot above the set Point (Lower
  • cut-off : Above set point
  • The LED (HT) blinks when temperature is overshoot above the set Point (Higher
  • Cut-off : Above set point)
  • The LED (BT) blinks when water is not present in the boiler tank.


 Microprocessor-based Safety Controller (Auto Reset) which will be cut off the heater Output Supply in case of over shoot of Low Set Temperature and it gives overshoot indication and alarm.

One Pt-100 Sensor Fitted inside the chamber. This will show the actual temperature on Safety Controller.


FOR BOILER SAFETY SYSTEM:-

Thermostat is fitted in the boiler tank. Boiler Safety Circuit will cut off the chamber output supply in case of Low Water Level and it gives overshoot indication and alarm.


 FOR TEMPERATURE SAFETY SYSTEM :-

• Two Safety set points are available. One is lower set point and another is Higher     set point.

• If temperature gets Over Shoot above the Higher Set Point, Higher Safety will be     cut off the chamber Power Supply.

• If temperature gets overshoot above the lower set point , Higher safety will be     cut off the heater Supply.

• If temperature gets Over Shoot above the Higher Set Point, Higher Safety will be     cut off the chamber Power Supply. Work on 220/230 Volts A.C.


MODEL NOINNER CHAMBER SIZEOUTER MILD STEEL POWDER COATED & INNER SS 304STAINLESS STEEL 304
SSI-104200 LITERSRs. /- eachRs. /- each

Write a review

Note: HTML is not translated!
    Bad           Good

Stability Chamber

  • ₹0

Seller information

View profile
Please sign in to contact Star Scientific Instruments

Tags: STABILITY CHAMBER