Product Features :
- Simultaneously measures and displays three parameters view individual parameter details at the press of a button
- Measures accuracy of up to ±0.002 pH and resolution of up to 3-decimal points
- Ion measurement capabilities with 3 digit resolution and 8 calibration points
- Measures 90.00 mg/L in DO concentration and 600 % in DO saturation – one of the widest Dissolved Oxygen measurement ranges offered in the handheld market
- Rugged and waterproof for applications in harsh environments
- Step-by-step prompts that guide users through set-up, calibration and trouble-shooting
- High/low alarm limits
- Meter automatically logs up to 500 readings with time and date in GLP-compliant format
- RS 232 through LED, USB / IrDA Interface Adapter
- Non-volatile memory protects information and meter settings, even when batteries run out
- Password protection to prevent tampering
Product Description :
Product Specification | Description |
pH Range | -2.000 to 20.000 pH |
Resolution / Accuracy | 0.1 / 0.01 pH / 0.001 pH ; ± 0.002 pH |
Calibration Points | 1 (Offset) to 6 points |
Auto-Buffer Recognition | Yes |
Slope & Offset Display | Yes |
Ion Range | 0.001 to 19900 ppm |
Resolution / Accuracy | 2 or 3 digits / 0.5 % full scale (monovalent) 1 % full scale (divalent) |
Calibration Points | Up to 8 |
mV Range | ± 2000.0 mV |
Resolution / Accuracy | 0.1 mV / ± 0.2 mV |
Temperature Range | -10.0 to 110.0 0C / 14.0 to 230.0 0F (Meter) 0 to 60.0 0C / 32.0 to 140.0 0F (DO) |
Resolution / Accuracy | 0.1 0C / 0.1 0F / ± 0.5 0C / ± 0.9 0F |
Dissolved Oxygen Range | 0.00 to 90.00 mg/L or ppm |
Resolution / Accuracy | 0.01 mg/L ; 0.01 ppm / ± 0.2 mg/L |
Calibration Points | 1 |
Probe | Galvanic with integral temperature sensor |
% Saturation of Oxygen Range | 0 to 600.0 % |
Resolution / Accuracy | 0.1 % / ± 2.0 % |
Salinity Correction Range | 0.0 to 50.0 ppt |
Resolution | 0.1 ppt |
Method | Automatic /manual |
Barometric Pressure Correction Range | 450 to 825 mmHg or 59.9 to 109.9 kP |
Resolution | 0.1 mmHg or 0.1 kPa |
Method | Automatic correction with built-in sensor |
Operating Temperature | 0 to 50 0C |
ATC | Yes |
Hold Function | Yes |
Ready Function | Yes |
Memory | 500 Data sets |
Inputs | DC Phono sockets, BNC, 8 Pin connector, 6 pin connector |
Communication Output | USB / IrDA Interface Adapter (for 600 Series Meter to PC Communication) to be ordered separately |
Power | 4 x 1.5 V ‘AA’ Alkaline batteries or 9 V DC Adapter, 500 mA |
Standard supply | pH electrode ECFC7252203B, Dissolved Oxygen probe ECDOHANDYNEW, DAS software, power adapter & carrying kit set (all probes have 3 m cable length). ORP electrode and Ion Selective Electrodes to be ordered separately |
Dimensions (L x W x H) | Meter 18.3 x 9.5 x 5.7 cm Boxed 23.5 x 16 x 15.5 cm |
Weight | Meter 460 g Boxed 800 g |