Click Image for Gallery
Bod Incubator
Product Details :
CONSTRUCTION
- Double walled construction, Inner chamber made of Stainless
- Steel & Outer chamber made of Stainless Steel or Mild steel powder coated.
- The chamber is insulated by filling
- (PUF) in the space between outer body and chamber to prevent
- Temperature loss. (Insulation-75mm)
- Double door – Outer metal body & Inner Glass Door.
- Inner door – made of imported transparent Glass which is usefull to view inner sample without opening the door and loss of temperature.
- Outer door with magnetic gasket & proper handle, lock & key.
- Supplied with Adjustable Stainless Steel shelves.
- Forced Air Circulating System with Fan for Temperature Uniformity.
- Illumination provided for inner chamber.
- Control panel with indicating Lamp for Compressor, Heater and on / off switch for mains.
- Castor wheels for easy movability.
TECHNICAL DATA
- Temp.Range: 5°C to 60°C
- Temp.Accuracy: ±0.5°C
- Temp.Uniformity:±1 °c
- Heating: Air heaters
- Digital Temp.Controller: Micro-processor based AutoTune P.l.D Digital Temperature Controller with PT 100 sensor.(Make:i-therm or equivalent)
- Resolution: 0.1 °C.
- Power Supply: 230 Volts A.C 50Hz Single Phase
- Cooling: CFC free compressor utilizing R 134A eco friendly refrigerant, with condenser, motor and relay or as per the requirement of customer for higher accuracy.
(Compressor make: Emerson or equivalent)
DOCUMENTATION
- We provide Manual & DQ, IQ, OQ, PQ documents compliant to competitive regulatory guidelines.
- We provide calibration certificates & Temperature Mapping Report for B.O.D Incubator, which are Traceable to national standards.
- We also provide S.O.P for B.O.D Incubator.
PRE INSTALLATION MANDATORY REQUIREMENT
- Room temperature around machine preferably at 25°C with air conditioning or a well-ventilated room With exhaust fan. However, surrounding temperature should not exceed 30°C.
- Stabilized input voltage of 230V A.C. Use of servo controlled stabilizer is recommened.
- Water Drain line with 1/2″ nozzle to be provided at floor level.
OPTIONAL ACCESSORIES
STAND BY REFRIGERATION SYSTEM
- Stand by compressor manual switchover facility with compressor time delay
PC/ PRINTER INTERFACE UNIT
- Facility to print records on printer with set values, actual values, date and time with variable print time
SOFTWARE
- 21-CFR PART 11 COMPLIANCE SOFTWARE
Model No. | Inner Chamber Size (WxDxH) | Size In Ltr. | No of Shelves | K.W |
---|---|---|---|---|
JDJ/BOD-1 | 18″ X 16″ X 20″ | 90 | 2 | 1.2 |
JDJ/BOD-2 | 20’’ x 20’’ x 28’’ | 175 | 2 | 1.2 |
JDJ/BOD-3 | 20″ x 20″ x 36″ | 225 | 3 | 1.2 |
JDJ/BOD-4 | 22″ x 22″ x 36″ | 270 | 3 | 1.7 |
JDJ/BOD-5 | 24″ x 24″ x 36″ | 320 | 3 | 1.7 |
JDJ/BOD-6 | 24″ x 24″ x 48″ | 440 | 4 | 2.0 |