HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Water
Product Details :
Product Code : HI9829
We have uniquely positioned ourselves as a dependable firm, engaged in manufacturing and supplying HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Water. This device is used to measure pH, dissolved oxygen, turbidity and temperature of water. To manufacture this device, our expert workforce uses quality grade material and components. The device comes with a microprocessor based multi-sensor probe. We offer this HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Water at pocket friendly prices.
Features:
- Light weight
- Portable and durable
- Easy to setup
Further Details:
The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.
Specifications
- pH Range : 0.00 to 14.00 pH
- pH Resolution : 0.01 pH
- pH Accuracy : ±0.02 pH
- pH Calibration : automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
- mV Range : ±600.0 mV
- mV Resolution : 0.1 mV
- mV Accuracy : ±0.5 mV
- ORP Range : ±2000 mV
- ORP Resolution : 0.1 mV
- ORP Accuracy : ±1.0 mV
- ORP Calibration : automatic at one custom point (relative mV)
- EC Range : 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
- EC Resolution : Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
- EC Accuracy :±1% of reading or ±1 µS/cm whichever is greater
- EC Calibration :automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
- TDS Range :0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
- TDS Resolution : Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
- TDS Accuracy : ±1% of reading or ±1 ppm (mg/L), whichever is greater
- TDS Calibration : based on conductivity or salinity calibration
- Resistivity Range : 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
- Resistivity Resolution : dependent on resistivity reading
- Resistivity Calibration : based on conductivity calibration
- Salinity Range : 0.00 to 70.00 PSU
- Salinity Resolution : 0.01 PSU
- Salinity Accuracy : ±2% of reading or ±0.01 PSU whichever is greater
- Salinity Calibration : based on conductivity calibration
- Seawater σ Range : 0.0 to 50.0 σt, σ₀, σâ‚â‚…
- Seawater σ Resolution : 0.1 σt, σ₀, σâ‚â‚…
- Seawater σ Accuracy : ±1 σt, σ₀, σâ‚â‚…
- Seawater σ Calibration : based on conductivity or salinity calibration