For Laboratory Stainless Steel High-Pressure Steam Sterilizer
ApplicationLaboratoryChamber Volume180 LMaterialStainless SteelShapeHorizontalMount TypeFloor Mounted AutoclaveChamber Dimensions450 x 450 x 900 mmBrandU-TechVoltage220VFrequency50HzPower400WMinimum Order Quantity1
Application
Laboratory
Chamber Volume
180 L
Material
Stainless Steel
Shape
Horizontal
Mount Type
Floor Mounted Autoclave
Chamber Dimensions
450 x 450 x 900 mm
Brand
U-Tech
Voltage
220V
Frequency
50Hz
Power
400W
Minimum Order Quantity
1
We are offering High-Pressure Steam Sterilizer.
Boiler is made from thick stainless steel sheet suitable located under the sterilizer. High grade flanged type heating elements are placed in the from side for easy replacement etc. Fitted with water gauge made of glass for water level, safety valve, water inlet and drain valves.
Provided with self locking safety door which cannot be opened when the chamber is under pressure. The clutch mechanism automatically disengages the threads of the radial locking system for precluding any eventuality of accident when the chamber is under pressure. A heat resistant neoprene rubber gasket is provided for totally safety of the Instrument.
Provided with electrically operated PIEZOSTAT , which economics the power consumption and limits the use of release valve which would frequently blow steam into the room. It cuts off the power supply to heaters when the set pressure is achieved and re-energises the heater when pressure falls down.
Two separate valves are provided for evacuating air and steam from inner chamber and jacket .A steam trap is fitted in the chamber discharge line to eliminate the condensate automatically. Panel consist of pressure control switch, main on/off switch, Indicators, relays etc.The sterilizer is provided with triple safety. First with pressure control switch , Two nos. spring loaded safety valves, and a dead weight safety valve.A PLUG SCREEN prevents the discharge line from choking. And it can easily be removed for cleaning. A power full ejector circulates the air throughout the chamber.
Operating Temperature and Pressure :
121°C., 1.2 to 2 kg./sq. cm.
Load : 6.0 to 18.0 KW
Product Details:
Provided with self locking safety door which cannot be opened when the chamber is under pressure. The clutch mechanism automatically disengages the threads of the radial locking system for precluding any eventuality of accident when the chamber is under pressure. A heat resistant neoprene rubber gasket is provided for totally safety of the Instrument.
Provided with electrically operated PIEZOSTAT , which economics the power consumption and limits the use of release valve which would frequently blow steam into the room. It cuts off the power supply to heaters when the set pressure is achieved and re-energises the heater when pressure falls down.
Two separate valves are provided for evacuating air and steam from inner chamber and jacket .A steam trap is fitted in the chamber discharge line to eliminate the condensate automatically. Panel consist of pressure control switch, main on/off switch, Indicators, relays etc.The sterilizer is provided with triple safety. First with pressure control switch , Two nos. spring loaded safety valves, and a dead weight safety valve.A PLUG SCREEN prevents the discharge line from choking. And it can easily be removed for cleaning. A power full ejector circulates the air throughout the chamber.
Operating Temperature and Pressure :
121°C., 1.2 to 2 kg./sq. cm.
Load : 6.0 to 18.0 KW
Product Details: