Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Hach Dissolved Oxygen Meter HQ30D Meter with LDO sensor

Hach Dissolved Oxygen Meter HQ30D Meter with LDO sensor

Product Details : 

  • AC Power Adapter and USB/DC Adapter:Optional
  • Automatic Buffer Recognition:Yes
  • Barometric Pressure Measurement:Automatic compensation of DO when using an LDO probe
  • Calibration:Demal (1D/ 0.1D/ 0.01D); Molar (0.1M/ 0.01M/0.001M); NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm); Standard sea water; User defined
  • Calibration Intervals/Alerts/Reminder:Off, Selectable from 2 hours to 7 days
  • Compliance Certifications:CE.WEEE
  • Conductivity measurement:Yes
  • Conductivity measurement: Temperature correction:None; Linear; NaCl Non-Linear Natural Water.
  • Conductivity Measurement Range:0.01 µS/cm – 200.0 mS/cm
  • Conductivity resolution:0.01 µS/cm – 0.1 mS/cm upon selected measuring range
  • Contents:No
  • Custom Calibration Standards:Yes
  • Data Export:Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
  • Data Memory:500 records/FIFO
  • Data Storage:Automatic, GLP ISO compliant reading data stored with calibration details.
  • Digital (intelligent) electrode inputs:1 channel
  • Display:Detailed mode/Large mode
  • Display Lock Function:Continuous / Auto-stabilization (“press to read”) / At Interval
  • Display Type:240 x 160 pixel LCD with backlight illumination
  • DO Measurement Range:0.1 – 20.0 mg/L (ppm) 1 – 200% saturation
  • DO Resolution:0.1
  • DO sensor calibration:* 100% (water-saturated air (100%) calibration; * 100% with 0 (water-saturated air (100%) calibration with 0 point ; * mg/L (calibration with a specified dissolved oxygen concentration (mg/L) solution) ; * mg/L with 0 (calibration with a specified dissolved oxygen concentration (mg/L) solution with 0 point);  * Factory (calibration with the default LDO calibration)
  • GLP Features:Date; Time; Sample ID; Operator ID
  • Inputs:1
  • Instrument:Portable
  • IP Rating:IP67
  • ISE Direct Measurement Range:Yes
  • ISE Electrode Calibration:2 – 5 Points
  • Languages:English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian
  • Measurement Method:Probe specific programmed method settings
  • Model:HQ30D – Multi/1 Channel
  • mV Measurement at Stable Reading:Yes
  • mV Measurement Range:-1500 – 1500 mV
  • mV Resolution:0.1 mV
  • Needed Cable Length:NA
  • Operating Error Messages:Clear text error messages displayed
  • Operating Humidity:90 % relative humidity (non-condensing)
  • Operating Interface:Soft Touch Keypad
  • Operating Temperature:0 – 60 °C (32 – 140 °F)
  • ORP Electrode Calibration:Predefined ORP standards (including Zobell’s solution)
  • Parameter:pH/Oxydo Reduction Potential (ORP); Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity; Dissolved Oxygen (DO); Biochemical Oxygen Demand (BOD); Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium
  • PC Data Transfer Software:HQD Series Meter Data Transfer Utility
  • pH Buffer Sets:Color-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45; DIN: 1.09, 4.65, 9.23; User-defined custom buffer sets
  • pH Electrode calibration:1 – 3 Calibration points; Calibration summary data logged and displayed
  • pH Measurement Range:0 – 14 pH
  • pH Resolution:Selectable: 0.001/0.01/0.1 pH
  • Printer:Yes, Optional
  • Probes included:None
  • Probe Type:Intellical Standard Laboratory or Rugged Field
  • Region:US
  • Salinity Measurement Range:0 – 42 (ppt) (‰)
  • Salinity Resolution:0.01 (ppt) (‰)
  • TDS Measurement Range:0.00 mg/L – 50.0 g/L NaCl
  • TDS Resolution:0.01 mg/L up – 0.1 g/L upon measuring range
  • Temperature Compensation:Automatic Temperature compensation for pH
  • Automatic Temperature compensation for pH
  • Temperature Measurement:°C or °F
  • Temperature Resolution:0.1
  • Type of Measurement:Portable/Field Water Quality Applications
  • Warranty:3 years
  • Weight:335 g (0.75 lb) without batteries; 430 g (0.95 lb) with

Write a review

Note: HTML is not translated!
    Bad           Good

Hach Dissolved Oxygen Meter HQ30D Meter with LDO sensor

  • Views: 64
  • Vendor Type: Supplier
  • Product Code: HQ30D
  • Availability: In Stock
  • ₹0

Seller information

  • R-Initiative Enterprises

  • R-Initiative Enterprises
  • Faridabad, India
  • Business Type :Supplier
View profile
Please sign in to contact R-Initiative Enterprises

Tags: Dissolved Oxygen Meter