Click Image for Gallery
De-Humidifier
Product Details :
These equipment are capable ofmaintaining Relative Humidity 35% RH to 45% RH & are mainly used in Pharmaceutical Laboratories Capsules, Strip packing, Tablet Section, Packing Rooms, Processing Industries, Printing & Lithography, Photographic Industries, Communication equipment rooms, Computer & data storage various other purposes Construction Heavy gauge construction of CRCA sheet or AISI Stainless steel, Robust angular structure removable casing panel makes all parts easily accessible for adjustments & service when required.
GMP
- Construction Heavy gauge construction of SS sheet SS 304, Robust angular structure removable casing panel makes all parts easily accessible for adjustments & service when required.
- Working of Environment Controller (De-humidifier) The equipment is based on refrigeration principle. It removes the moisture content of humid air in an enclosed room & condenses the moisture of the humid air into water which continuously drops into tray. No chemicals or dehydrating substances are used Relative humidity can be maintained depending upon the cubic feet volume, the temp & no. of occupants in the room. The walls & ceilings should be vapour proof to minimize infiltration of moisture into the room.
- Refrigeration system It is fitted with a hermetically sealed compressors to operate on 230 volts , Single phase 50Hz, with heat exchanging coil, water condensing coil & fan motor assembly. The unit is mounted on a trolley with a water collection tank at the bottom.
- DimensionsHorizontal Model overall Size : 30”H x 18”W x 18”D Vertical Model overall Size : 42”H x 22”W x 24”D Application The following are the required conditions for installation of Environmental controller (Dehumidifier)
- CAPACITYROOM VOLUME NO OF OCCUPANTS IN THE ROOM 1.0 Tonne 2500 cu. ft. 5 1.5 Tonnes 3750 cu. ft. 7 2.0 Tonnes 5000 cu. ft. 9 Room Temperature When operating the equipment the room temp. will tend to rise on account of its moisture removal latent heat load & the electrical motor operating in the equipment, A sufficient capacity Air Conditioner given below has to be installed along with the Environmental Controller (De-Humidifier) The total heat load thus added to the room is given under.
- Environmental Controller (Dehumidifier) Capacity Approx. Heat Load added to the room Air Condition 1 Tonne 2500 BTU 1 Tonne 1.5 Tonnes 9000 BTU 1.5 Tonnes 2 Tonnes 12000 BTU 2 Tonnes RH Conditions : A few of the typical temperature & the corresponding Relative Humidity conditions attainable in a room are given here under Room Temp. is maintained at RH of the room (approx) 70 ˚C F or higher 45 % 74 ˚C F or higher 40 % 81 ˚C F or higher 45 %