Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Horizontal Rectangular Double Door Autoclave

Features:

  • Double Door
  • Dry and wet sterilization
  • Confirm to EMD 93/42/EEC
  • PID Controls
  • Graphic & Logs
  • Radial Lock
  • On Line Printer
  • Space between boiler and outer shell works as air insulation.
  • Electrical cord and plug to work on 440 volts 3 Phase A.C.
  • Supplied along with as standard scope.

RAPID COOLING SYSTEM

Bio Gene Egg Decontamination Autoclave is fitted with Rapid cooling System mechanism. These Mechanisms are built with heavy duty cooling coils fitted around the inner chamber of the Egg Decontamination Autoclave.

Air Blast Cooling:

Air Blast Enter the Egg Tray Decontamination chamber on completion of the sterilization cycle to speed the up the Rapid Cooling and forces the steam to collapse as large forced cool Air Blast occupies the space displacing the steam is the chamber at a regulated Air Pressure Controlled Through the Value. The Bio Gene Decontamination Autoclave. This Mechanism is also operated through the Manual value in case of any Failure. TROLLEY MILD STEEL FOR 42 TRAYS 1 tray for 42 eggs Tray size 309 X 295 X 81 mm CARRIAGE SS 304 Microprocessor Digital Controller (Optional)


WORKING TEMPERATURE:-

Bio Gene Decontamination Autoclave Horizontal Rectangular Autoclave as per the international standards and guidelines our Horizontal Rectangular autoclaves have a working temperature of 1210c. However for specific requirements our autoclaves can be upgraded to be used for up to 121c.

WORKING PRESSURE:-

Bio Gene Decontamination Autoclave Horizontal Rectangular Autoclave Working Pressure controlling device can be adjustable at variable pressure from 5 psi to 20 psi. Working sterilization temp : 121°C Working sterilization pressure : 15 psi (1.2 Kg/cm2)

PRESSURE RANGE:

Bio Gene Decontamination Autoclave Horizontal Rectangular Autoclave Normal pressure range of our autoclave is 5 psi to 22 psi.

PRESSURE CONTROL:

Bio Gene Decontamination Autoclave Horizontal Rectangular Autoclave The pressure inside our Decontamination Autoclave horizontal rectangular autoclave is controlled through a semi automatic electro mechanical device called Piezostat, which controls the pressure inside the chamber and cuts of the current from the heater whenever the pressure exceeds the set pressure value of the autoclave, thus making it very safe and energy efficient.

HEATING:
Bio Gene Decontamination Autoclave Horizontal Rectangular Autoclave Heating process in our triple walled Horizontal Rectangular autoclave is done through specially designed water heaters of suitable wattage to ensure optimum sterilization time in every sterilization cycle.

Specifications:

MODELBTI-RA-DD10BTI-RA-DD12BTI-RA-DD16BTI-RA-DD55
MakeBIO GENE
Technical Matrix ForLab
Temperature range115ºC-121ºC 
(Optional 132 ºC and above)
Trays2
Temperature SensorPT 100
WORKING PRESSURE15 to 22 p.s.i
Inner chamberStainless Steel Sheet (SS-304)
Outer chamberStainless Steel Sheet (SS-316)
Temperature ControllerMicroprocessor Based Programmable Controller
Heat Load6 KW/ 9KW/ 9KW/ 9KW
Nominal Voltage220-230 Volts, 50Hz Single Phase
SIZE450 x 450 x 900mm600 x 600 x 900mm600 x 600 x 1200mm900 x 900 X 1800mm
CAPACITY-LTRS180 LTR340 LTR450 LTR1550 LTR