Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Autoclaves (Vertical Type)

Autoclaves (Vertical Type)

Product Features:

Microprocessor control with reliable safety functions guarantees optimum sterilization temperature


Performance

  • Microprocessor controller and temperature calibration function allows for high precision temperature control
  • Sterilization temperature at 110 to 123°C
  • Melting* temperature at 60 to 100°C


Liquefaction of coagulated agar media

  • Automatic sterilization system for unattended operation
  • Heating > Check safe > Sterilization > Sterilization safe > Exhausting > End
  • Convenient operation modes for various uses
  • Standard modes and program modes are listed in detail as below tables
  • Temperature calibration function


Convenience

  • Conveniently monitored by an independent control display, sterilization process display, and pressure gauge
  • VFD for visualization of temp, pressure (optional), timer, warning alert checks
  • LED lamps for sterilization process check
  • Easy pressure check with the standard gauge attached to the front
  • Vertical type autoclaves which allow for top loading are suitable for high volume sterilization
  • Baskets are stackable two high or even more levels, which secure inside the chamber space requirements
  • Low-maintenance
  • The chamber is constructed of stainless steel which is superiorly resistant to corrosion
  • Easy to replace silicone gasket
  • Convenient documentation with the optional data recorder
  • Dot type recorder(6 point) allows for precise documentation


Safety

  • Mechanical safety devices
  • Over current protection
  • Over temperature protection by automatic power cutoff
  • Over pressure protection by automatic and manual safety valve
  • Safety warning systems
  • Over temperature warning
  • Low temperature warning
  • Low water level warning
  • Low heat warning if the temperature does not reach the sterilization or melting temperature
  • Sterilization fail warning if the operation is unexpectedly stopped during sterilization process
  • Slide opening door with plastic cover of low thermal conductivity prevents burns from the contact


Product Description :
ModelST-50GST-65GST-85GST-105G
ControlMicroprocessor PID control
Chamber volume (L/cu ft)50/1.865/2.385/3.0105/3.7
Temperature 1)Sterilization temp. (℃/℉)110 to 123/198 to 221.4
Melting temp.(℃/℉)60 to 100/108 to 180
PressureSterilization at 121℃ (kg/cm 2)1.1 to 1.2
Gauge range in analog (Mpa)– 0.1 to 0.6
SafetyOver temperature protector/Pressure safety valve/Over current protector
Warning alert (over temp./low temp./low heat/sterilization fail/low water level)
Timer0 to 999 min.
DimensionNo. of baskets (standard / max.)2/22/22/22/2
Load per baskets (Kg / lbs)10 / 22.0
Basket (OxH) (mm / inch)380×180/14.9×7.1380×230/14.9×9.1380×330/14.9×13.0380×405/14.9×15.9
Interior (WxH) (mm / inch)400×458/15.7×18.0400×558/15.7×21.9400×758/15.7×29.8400×908/15.7×35.7
Exterior (W×D×H) (mm / inch)624x672x870/24.6×26.5×34.2624x672x971/24.6×26.5×38.2624x672x1083/24.6×26.5×42.6624x672x1233/24.6×26.5×48.5
Exterior with exhaust tank
(W×D×H) (mm / inch)
722x672x870/28.4×26.5×34.2722x672x971/28.4×26.5×38.2722x672x1083/28.4×26.5×42.6722x672x1233/28.4×26.5×48.5
Net weight (Kg / lbs)94.5/208.399.5/219.4104/229.3110/242.5
Electrical requirements
(230V, 50/60 Hz)
14.3A14.3A14.3A21.3
Cat. No.AAHL1015KAAHL1025KAAHL1035KAAHL1045K

Write a review

Note: HTML is not translated!
    Bad           Good

Autoclaves (Vertical Type)

  • ₹0

Seller information

  • International Trade Links Instru

  • International Trade Links Instrumentation Pvt. Ltd.
  • Mumbai, India
  • Business Type :Supplier, Manufacturer
View profile
Please sign in to contact International Trade Links Instru

Tags: Autoclave