Air Conditioner Simulator
Descriptions :
The main unit consists of two different circuits for R-134 and R-22.R-22 circuit consists of an air-cooled condenser with cooling fan and its speed regulator expansion devices (expansion valve along with solenoid valve and capillary tube) rotameter as flow measuring device, separate two row cooling coil and 1 h.p. Compressor. The R-134 circuit consist of an air-cooled condenser, capillary tube water immersed evaporator and 1/3 h.p. Compressor. Energy meter, voltmeter, ampere meter, digital temperature indicator with thermocouples, anemometer is for measurement of velocity of air in the duct, exhaust type fan used for air flow system, pressure gauges, high pressure cut out, thermostat, filter dryer and hand shut off valves etc. are provided.
Features:
- Simulation of different conditioned air of varying temperature and humidity.
- Demonstration of vapour compression refrigerant cycle for R-12 and R-22 refrigerants.
- Provision for sensible and latent heat loads in air conditioning space.
- Scope of winter air conditioning.
- Complete range of psychometric experiments.
- Heat load related experiments.