Biosafety Cabinet Class II A2
Product Details:
Salient Features of Micro-Processor Controller :
Manual Function Mode
- 2.5inch 128 x 64pixel blue/white graphic LCD display.
- Motorized Door on up/down touch keys.
- UV/florescent light/power on/off soft touch key.
- Blower Motor on / off in touch key.
- Inter Socket Manual on / off touch key.
- Buzzer Silent soft touch key.
- Power on / off soft touch key.
- Display of air pressures in the LCD screen.
- Alarm if the door is opened beyond 200 mm.
- Timer for UV light (0-59 minutes).
- User Program
- UV timer
- UV Lamp Life
- Reset UV hours
- To set Auto clean Auto Clean Mode
- Change Password
Auto Function Mode
- Display of down flow and up flow by deferential pressure.
- Alarm is activated in case of airflow deviation over 20%.
- Blower will go off when the door is closed.
- Fluorescent lamp will not be active when UV is on.
- UV will not get on when florescent is on.
- Blower will be shut off when UV is on.
- Alarm if the door is opened beyond 200 mm.
- Timer for UV light (0-59 minutes).
- Biosafety Cabinet Class II A2
- Biosafety Cabinet Class II A2 Manufacturers in India
- Biosafety Cabinet Class II A2 Manufacturers in India
- Biosafety Cabinet Class II A2 Manufacturers in India
Salient Features of Manual Machine:
Manual Function Mode
- 2.5inch 128 x 64pixel blue/white graphic LCD display.
- Motorized Door on up/down touch keys.
- UV/florescent light/power on/off soft touch key.
- Blower Motor on / off in touch key.
- Buzzer Silent soft touch key.
- Power on / off soft touch key.
- Display of air pressures in the LCD screen.
- Alarm if the door is opened beyond 200 mm.
Auto Function Mode
- Display of down flow and up flow by deferential pressure.
- Alarm is activated in case of airflow deviation over 20%.
- Blower will go off when the door is closed.
- Fluorescent lamp will not be active when UV is on.
- UV will not get on when florescent is on.
- Blower will be shut off when UV is on.
- Alarm if the door is opened beyond 200 mm.
Technical Specification :
- Type A2 Class II Biological Safety Cabinets have an open front design provided with negative pressure generation module. Type A2 cabinets are typically used for biosafety levels 1 through 3 and are suitable for work with chemicals, as long as vapors are not hazardous and will not interfere with the work when recirculated, cabinets protect from contamination of the works, experiment or process from outside contaminants.
- The ergonomic internal design, the airflow aerodynamics, the built-in safety devices and the advanced level of construction, ensure the highest performance at the most stringent safety levels, as specified by international standards. The system combines a multitude of design, construction and technological considerations to provide optimum operator, product and environmental protection. Stainless steel construction and simple design make it easy to clean after use. The powder coating finish prevents microbial / bacterial growth on the exterior side and delivers a sleek and graceful appurtenance.
Salient Features:
- A front access opening with careful maintained inward airflow. An internal blower draws sufficient room air through front grill to maintain a minimum calculated or measured average FPM at the face opening of the cabinet.
- The contaminated air is drawn by the blower through the plenum of the cabinet, were approximately 70% of the air recirculated through the HEPA filter back to the work area, 30% of the air is exhausted from a common plenum at the top through a HEPA filter.
- Room air enters through a blower / motor passes through a pre-filter in to the work area as the vertical unidirectional airflow.
- HEPA filter exhaust air in Type A2 cabinet maybe recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.
- HEPA filter having efficiency rating as high as 99.99% with cold DOP & 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micro and larger.
- Negative pressure surrounds the work area and maintains inward air flow in chamber.
- Aerodynamics air flow grill maintains safety and prevents blockage.
- High efficiency pre-filter use increases the life of HEPA filter.
- Unit has UV germicidal light for sterilization and fluorescent lamp for illumination.
- Maximum safe door opening height 8” (Access port – Work aperture)
- Personal protection from harmful agents used inside the biosafety cabinet.
- Product protection from contamination of the works, experiment or process from outside contaminants.
- Environment protection from contamination of the works, experiment or process from outside contaminants.
- Manufactured as per NSF/ANSI 49 USA standard and EN 12469 European guidelines.
- Machines qualifies particle count test, Filter Integrity Test, Velocity Test, DOA/POA test, Fluorescent Light and UV light test.
- Machine is fitted with castor wheels for ease of movement and fixed with rubber leveling pad. .
- We are Biosafety Cabinet Class II A2 manufacturers in India to entire world since 2017 by us with assured required safety and industrial quality features
SPECIFICATIONS OF BIOSAFETY CABINET A2 MODEL | |||||
---|---|---|---|---|---|
Main Filter | HEPA Filter (99.97% Efficient At 0.3-Micron Particulates To Meet Air Quality ISO Class 5 Equivalent To US FED STD 209 B, Class 100. | ||||
Pre-Filter | Highly Efficient Washable Pre-Filter Efficiency 90% Down To 10 Microns. | ||||
Illumination | Fluorescent Lamp Of 10/20/30/40 W (Greater Than 800LUX As Per Guidelines Laid In US Federal Standard. | ||||
Sterilizing | UV Germicidal Tube Of 254mn Wavelength. | ||||
Front Door | Motorized Door Lifting Arrangement At Press Of A Button. Door Made Of Toughen Glass (Polycarbonate Door Optional). | ||||
Utility | Gas / Air Cock And Multipoint 15/5 AMP Electric Socket. | ||||
Magnehelic Gauge | Magnehelic Gauge Analogue Type For Main HEPA Filter. | ||||
Input Supply | AC 230V, 50/60 Hz | ||||
Cabinet – MOC | Cold Rolled Powder Coated For STD Model. | ||||
Work Table | Stainless Steel 304 Grade (Optional Stainless Steel 316). | ||||
Internal Work Zone Dimension | 2 X 2 X 2”(Ft), 3 X 2 X 2 (Ft), 4 X 2 X 2 (Ft), 6 X 2 X 2 (Ft) | ||||
Size Of HEPA Filter (LxDxH) | 2 X 2 X 3”(Ft), 3 X 2 X 3”(Ft), 4 X 2 X 3”(Ft), 6 X 2 X 3”(Ft) | ||||
No. Of HEPA Filter | 2 |