Click Image for Gallery
EXA 3000 BMD Machine
Product Details:
Usage/Application | Hospital, Diagnostic Center |
Brand | OsteoSys |
Weight | 27.45 kg |
Measurement Method | pDXA(Peripheral Dual Energy X-ray Absorptiometry) |
Measurement Parameter | BMD,T-score,Z-score,BMC,Ratio of T-score and Z-score |
QC Check | Daily QC phantom |
Dimension | 670 x 410 x 373 mm |
Power Consumption | 100~240 VAC,50~60 Hz |
Model | EXA 3000 |
Scan Time | 5 sec. (Calcaneus),5 sec. (Forearm) |
Scan Sites | Calcaneus (Heel) & Forearm |
X-Ray Detector | CCD Detector |
X-Ray Source | Stationary anode X-Ray tube |
Precision & Accuracy | 1% (Based on QC Phantom) |
Operating System | Window XP,2000 and Vista |
We are among the reputed organizations, highly engaged in providing an optimum quality range of EXA 3000 BMD Machine. EXA-3000 is the one and only pDXA BMD device for measuring bone density of wrists and ankles, the areas the WHO recommends for measurement. It boasts of the quickest scanning speed of fewer than 5 seconds based on the Cone Beam method and the strength that only DXA can offer as it allows an operator to measure a patient without having to take off their socks or stockings. It is a device for quick and no-fuss measurement and diagnosis.
Key Features of EXA 3000
- Measure two spots: forearm & calcaneus (heel).
- Support optimized diagnosis software (BMD, BMC, T-Score, Z-Score).
- Easy to install and move.
- Windows XP-based graphic window makes the operation easier for any users.
- Accurately measure the age of the wrist by measuring articular bone of the wrist.
- High-resolution image (real image) as good as X-ray images.
- Comprehensive analysis including growth potential, age and nutritious state and trend of bones.
- Possible to measure fingers, carpal bones and calcaneus.
- Superior accuracy and repeatability.
Strengths of the tester
- Measure WHO-recommended sites (forearms, heels).
- Recognized as the quickest tester with 5 seconds or less in measuring time, thanks to Cone Beam.
- Easy to measure patients, no extra spending of consumables and accurate measurement.
- Automatic soft tissue calibration and distinction of bone boundaries.
- Use software to prevent spots which have a high number of trabecular bones which are clinically meaningful (=Lowest Bone Density) and accordingly to errors by operators or patients.
- Automated measurement and quality assurance, minimizing errors by operators or patients.
- The radiation level is 0.1 mSv, which is equivalent to the emission level of natural rays, not requiring any separate radiation blocking room.
- Possible to evaluate Future Fracture Risk and examine the trend.
- Excellent repeatability by being designed to place feet or wrists at the right spots.
- Possible to predict hereditary growth potential and future height through an examination of the childrens growth plate.