Click Image for Gallery
Maglumi 800 Fully Automated Chemiluminescence Analyzer
Product Details :
Model Name/Number | Maglumi 800 |
Brand | Snibe |
Detection Method | Chemiluminescence (CLIA) |
Assays | Complete Covid-19 Test Parameters, Thyroid, Cardiac, Diabetes |
Sample Type | Whole Blood, Serum, Plasma |
Sample Volume Range | 10-100 |
Throughput | Upto 180 Tests Per Hour |
Total Assay Capability | 120+ Parameters |
On Board Capacity | Please refer to the brochure |
Sample Capacity | 78 Samples |
Time To First Result | 17 Mins |
Reagent System | Closed |
Reagent On Board Stability | 1-13 Days |
- Throughput: 180 tests/hour
- Random access, batch mode or STAT
- Non-enzyme
- Throughput: 180 tests/hour
- Random access, batch mode or STAT
- Non-enzyme involve flash chemiluminescence
- Long stability of reagents
- ABEI label, very stable in acid and alkaline buffers
- Starter reagents consists of NaOH, unaffected by storage conditions
- Reagent integral: All components including calibrators, diluents inside the cartridge itself.
- Throughput: 180 tests/hour
- Random access, batch mode or STAT
- Non-enzyme involve flash chemiluminescence
- Long stability of reagents
- ABEI label, very stable in acid and alkaline buffers
- Starter reagents consists of NaOH, unaffected by storage conditions
- Reagent integral: All components including calibrators, diluents inside the cartridge itself. Easy and cost effective inventory management. Inter lots issues and traceability improvement
- 10 Point Master Curve: More accuracy and better analytical measurement range and cost effective inventory management. Inter lots issues and traceability improvement10 Point Master Curve: More accuracy and better analytical measurement range flash chemiluminescence
- Long stability of reagents
- ABEI label, very stable in acid and alkaline buffers
- Starter reagents consists of NaOH, unaffected by storage conditions
- Reagent integral: All components including calibrators, diluents inside the cartridge itself. Easy and cost effective inventory management. Inter lots issues and traceability improvement
- 10 Point Master Curve: More accuracy and better analytical measurement range
- Reagent Feature
- Integrated kit with calibrator, ready to use
- Controls provided with the kits
- Super paramagnetic microbeads solid phase
- RFID tag with master curve stores all information of reagents
- 2 - Point calibration, to adjust master curve
- Reagent Loading
- On board 9 reagent loading facility.
- Continuos loading
- RFID reads all reagent information
- Refreigerated reagent area
- Contact us for demo and best offer price
- Monitors reagent liquid level
- Optional ratio for high sample dilution
- Auto dilution for high titer samples
- Clot detection
- 40 samples slot