Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Potentiometric Titrator
Potentiometric Titrator
Product Details:

Labindia Analytical Potentiometric Titrator Titra+ comes with quick interchangeable imported burette assemblies with intelligent recognition for its volume size.This potentiometric autotitrator is perfect for all types of industrial applications. The Titra+ has composite differential electrode amplifier unit for potentiometric and voltametric/Karl Fisher titration having connectivity to various electrodes.
Three standard modes of titration namely incremental, equilibrium and cut-off mode is provided to perform all types of titrations. There is a real time clock for time display and report printout with run time indication. With a balance interface to directly transfer the weight. 50 methods can be stored and report of method parameter can be printed in Titra+.
Principle
Volume determination by equivalence point, end point or pH STAT
Control

Microcontroller based (Advanced version of microprocessor).

mV range

± 3200 mV

Accuracy

±0.1mV (±0.0016 pH)

Amplifier input impedance

> 10"12 ohms

Burette Resolution

1/20000 for 1o ml volume

Burette Volume

5 ml, 1o ml & 25 ml available

Filling time

<20 sec

Keyboard

Alphanumeric splash waterproof polyester soft keys

Display

40 x 2 line back lighted liquid crystal display (LCD)

Titration Head

(a) Manual stand with swivelling arm

Stirrer System

Microcontroller based variable speed, high torque vortex stirrer with digital indication. Magnetic Stirrer optional.

Sensors

(1) Electrodes for Potentiometric titration - {pH, Ion, Redox, Argentometric). a) Any combination electrode. b) Differential Electrode System comprising sensing (Indicator) Electrode with BNC Connector and Reference Electrode with 4mm Banana Connector. (2) Electrode for KFNoltametric titration with BNC/TNC Connectors. (3) Temperature sensor (PRT/PT100)

Calibration

3-point Calibration with user entered buffer values and standardisation with 7 pH buffer

End Point detection

a) Potentiometric, b) Voltametric, c) Thermometric and Photometric.

Cut-off criteria

a) Volume b) End point c) mV/pH

Methods

1) Titrations –
a) Acid base,
b) Nonaqueous
c) Redox
d) Preciptiation
e) Complexometric
f) back titration
2) KF titration (Optional)

Results

a) Molarity
b) % Assay (wt)
c) % volume (ml)
d) ppm
e) mg/I ijmg/g g) g/I h) meq/I I) moVkg
j) TAN and TBN for oil samples.

Method Storage

50 methods with parameters.

Titrant Molarity storage

20 Values

REPORT FORMAT

1) Method parameter.
2) Titration analysis report.
3) Titration analysis condensed report.
4) Titration data table. 5) Titration graphic report -
i) µIv/s mV
ii) µIv/s First derivative
iii)µIv/s Second derivative
iv) µIv/s Time
6) Auto evaluation report
7) Statistics report
8) End Point
Titration report
9) Calibration report

Input/Output peripheral interface

a) Parallel Port :1No. for printer
b) Serial Port : 2 Nos. for Balance & PC

Power

Write a review

Note: HTML is not translated!
    Bad           Good

Potentiometric Titrator

  • ₹0

Seller information

View profile
Please sign in to contact Labindia Analytical Instruments

Tags: Analytical Equipment