Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Waters Alliance 2695 HPLC

Waters Alliance 2695 HPLC

Product Details :

Backed by a team of technocrats and skilled professionals, we are highly engaged in trading and supplying an extensive range of Waters Alliance 2695 HPLC. The offered product is manufactured by reliable vendors, who use a premium grade components and modern technology in strict compliance with the industry laid norms and standards. Our offered product is highly demanded in the scientific laboratories. We offer this product to our clients at reasonable prices.


Features:

  • Reliability
  • High performance
  • Trouble free operations


Solvent Conditioning:

  • Vacuum degas,two
  • operating modes, four
  • Chambers, < 500 µL internal volume per chamber
  • Programmable Flow Rate Range: 0.000 and 0.010 to 10.000 mL/min. in 0.001 mL/min. increments
  • Effective System Delay Volume: < 650 µL, independent of backpressure @ 1 mL/min.
  • Plunger Seal Wash: Integral, active, programmable
  • Gradient Profiles: Eleven (11) gradient curves (including linear, step [2], concave [4], and convex [4])
  • Maximum Operating Pressure: 5000 psi. (345 bar) (0.010 - 3.000 mL/min) Programmable upper and lower limits
  • Pressure Ripple: <2.5% (1 mL/min., degassed methanol, at 1700 psi backpressure)Composition Range: 0.0 to 100.0%, in 0.1% increments
  • Composition Accuracy: ± 0.5% absolute, independent of back pressure (Proportioning Valve Pair Test, [degassed methanol: methanol/propylparaben, 2 mL/min., 254 nm])
  • Composition Precision: 0.15% RSD or 0.02 min. SD, whichever is greater, based on retention time. (Degassed methanol:water, 60:40 dial-a-mix, 1 mL/min., 6 replicates, phenone mix, 254 nm)
  • Flow Precision: 0.075%RSD or 0.02 min. SD, 6 replicates, based on retention time or volumetric measures (0.200 - 5.000 mL/min.), iso cratic premix
  • Flow Accuracy: ± 1% or 10 µL/min. whichever is greater, (0.200 - 5.000 mL/min.), (Degassed methanol, at 600 psi back pressure)


Sample Management:

  • Number of Sample Vials: 120 vials, configured in 5 carouselsof 24 vials each
  • Number of Sample Injections: 1 to 99 injections per sample vial
  • Sample Delivery Precision: Typically < 0.5% RSD, 5 - 80 µL (Degassed methanol: water, 60:40 dial-a-mix, 1 mL/min., 6 replicates, phenone mix, 254 nm)
  • Sample Carryover: < 0.1%
  • Injection Accuracy: ± 1µL (± 2%) (50 µL, N=6), Sample: 100% degassed water, Analytical solvent: 100% degassed methanol
  • Advanced Operations: Stat runs, Auto additions, Auto standards
  • Injection Volume Range: 0.1 to 100 µL, standard; 0.1 to 2000 µL, with optional sample loop
  • Injector Linearity: > 0.999 coefficient of deviation (1 to 100 µL)


Physical Specifications:

  • Physical Size: (W x H x D) 23in. (58cm) x 22.5in. (57cm) x 23.5in. (60cm)
  • Weight: 130 lb. (59 Kg)


Additional Information:

  • Item Code: 2001

Write a review

Note: HTML is not translated!
    Bad           Good

Waters Alliance 2695 HPLC

  • Views: 215
  • Product Code: SCIN000028
  • Availability: In Stock
  • ₹0

Seller information

View profile
Please sign in to contact Scientific Instruments

Tags: HPLC System